SpeedFace-V3L(Lite) User Manual
P a g e
|
61 Copyright©2023 ZKTECO CO., LTD. All rights reserved.
Function Description
Function Name
Description
Gate Control Mode
It toggles between ON or OFF switch to get into gate
control mode or not.
When set to ON, the interface removes the Door lock
relay, Door sensor relay, and Door sensor type options.
Door Lock Delay (s)
The length of time that the device controls the electric
lock to be in unlock state.
Valid value: 1~99 seconds.
Door Sensor Delay
(s)
If the door is not locked and is left open for a certain
duration (Door Sensor Delay), an alarm will be
triggered.
The valid value of Door Sensor Delay ranges from 1 to
255 seconds.
Door Sensor Type
There are three Sensor types:
None
,
Normal Open
,
and Normal Close.
None: It means the door sensor is not in use.
Normal Open(NO): It means the door is always left
open when electric power is on.
Normal Closed(NC): It means the door is always left
closed when electric power is on.

Other manuals for ZKTeco SpeedFace-V3L (Lite)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ZKTeco SpeedFace-V3L (Lite) and is the answer not in the manual?

ZKTeco SpeedFace-V3L (Lite) Specifications

General IconGeneral
BrandZKTeco
ModelSpeedFace-V3L (Lite)
CategoryIntercom System
LanguageEnglish

Related product manuals