Chapter 43 Alarm Commands
IES-612-51A User’s Guide
285
The following example displays the port alarm thresholds for all ports. “ifindex” identifies the
interface.
43.5 Alarm Port Set Command
Syntax:
ras> alarm port set <all|enet1|enet2|port> <severity>
where
This command sets the alarm severity threshold for recording alarms on an individual port(s).
The system reports an alarm on a port if the alarm has a severity equal to or higher than the
port’s threshold.
The following example has the IES-612-51A only record critical alarms on DSL port 7.
43.6 Alarm Tablelist Command
Syntax:
ras> alarm tablelist [<alarm>|all] [<severity>|all]
[<fac>|all][<target>[,<target>]] [<condition>|all]
where
Figure 139 Alarm Port Show Command Example
ras> alarm port show
no ifindex severity
----- ---------- -----------
01 01 minor
02 02 minor
03 03 minor
04 04 minor
05 05 minor
==================================== SNIP =================================
Press any key to continue, 'e' to exit, 'n' for nopause
<all|enet1|enet
2|port>
=
Ports on the IES-612-51A.
Figure 140 Alarm Port Set Command Example
ras> alarm port set 7 critical
<fac> =
The log facility (local1~local7) that has the device log
the syslog messages to different files in the syslog server.
See your syslog program’s documentation for details.
<target> =
snmp|syslog|all The type of alarm messages that the
device is to send (SNMP, syslog or all).