Configuration manual for 2N IP intercoms
159 / 282
released.
Switch locking and holding can be controlled by time profiles among others. It is not
recommended that a time profile be used for the locking function (the time-profile based lock
control is present in the device for legacy switch compatibility reasons) because this case results
in switch unlocking at the end of the time profile despite manual switch locking.
The current combination of these two functions is shown by theCurrent switch
functionparameter(Normal lock and hold are off; Held lock is off and hold is on; Locked
lock is on regardless of the hold setting).
Check after restart whether or not the lock/hold is controlled by a time profile. If so, the given
function is activated/deactivated according to the time profile setting. If not, the last locking
state before the device power off is set, or hold is set to inactive (the switch is not held).
If a switch is active, you can:
activate any logical output of the intercom (relay, power output).
activate the output to which the2N
®
IP Intercom - Security Relaymodule is connected.
send an HTTP command to another device.
The switch can work in the monostable or bistable mode. The switch is switched off after a
timeout in the monostable mode and switched on with the first activation and off with the next
activation in the bistable mode.
The switch signals its state:
by a programmable beep or a predefined user sound.
by a LED indicator if available in the intercom model.
by an open-door icon on the display if available in the intercom model.

Other manuals for 2N IP series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2N IP series and is the answer not in the manual?

2N IP series Specifications

General IconGeneral
CategoryIntercom System
Network Interface10/100 Mbps Ethernet
ConnectivityEthernet
IntegrationSIP
Ingress ProtectionIP54
Operating Voltage12V DC
Audio CodecG.711
Supported ProtocolsSIP, RTSP, HTTP, HTTPS
Supported LanguagesMultiple

Related product manuals