Ascotel® IntelliGate® 150/300 as of I7.9
Installation 105
syd-0210/1.7 – I7.9 – 12.2009
Cable Requirements
Tab. 40 Requirements for an AD2 bus cable
Installation rules
If an Ascote DECT radio unit is used, do not connect any other system terminal
to the same AD2 bus.
Do not use any terminating resistors at the bus extremity.
Avoid using different cable cross-sections on the same bus
Use the supplied cables for connecting the terminals
Cabling of AD2 terminals is restricted to pairs of a separate dedicated cable(s)
1)
.
Terminals
The following system terminals can be operated on the AD2 bus:
System Terminals
OfficePocket Adapter
Ascotel® DECT radio unit
The terminals on an AD2 bus are addressed via a single-digit terminal selection
digit (TSD).
Example:
The address of a terminal with TSD 2 on AD2 interface 0.5 on the mainboard is
0.5-2.
Core pairs x cores 1 x 2 or 1 x 4
Stranded yes
1)
1)
Note: max. 25 m can be crossed unstranded.
(CH: Applies also to cable type G51)
Wire diameter, core 0.4…0.6 mm
Screening recommended
Characteristic impedance < 130 Ω (1 MHz)
1)