Ascotel® IntelliGate® 150/300 as of I7.9
172 Operation and Maintenance
syd-0210/1.7 – I7.9 – 12.2009
The system configuration data (User No., User configuration, etc.) of the terminals
on the new ports is created as new data (initialization values).
Tab. 79 Example: Expanding the number of terminal or network interfaces
6. 3. 3. 4 Change slot
Interface cards can be moved to a different slot. The terminal configuration data of
the system terminals can be transferred.
Procedure:
1. Change the slot and put the PBX into operation again. Similar procedure as de-
scribed in "Replacing a defective interface card", page 170.
Note:
The wiring adapter must also be changed to the corresponding slot.
Any incorrectly fitted or missing wiring adapters are signalled by a red
flashing LED on the display after start-up (see "Wiring Adapter Mal-
function Mode", page 187).
2. Connect the system terminals to the ports of the new slot.
3. Re-configure port allocation using the AIMS Configuration Manager.
4. Insert the card in the new slot in AIMS and remove it from the old slot. The con-
figuration data at the old slot location is now deleted.
Note:
Not all cards can be equipped on all slots (see "Component mounting
rules", page 82).
SC-08AD2 → SC-16AD2 The configuration data of terminal interfaces 9...16 is created as new data.
ISDN-04ST → SC-08AD2 The configuration data of all 8 terminal interfaces is created as new data.