Ascotel® IntelliGate® 150/300 as of I7.9
Installation 75
syd-0210/1.7 – I7.9 – 12.2009
4. 4 Power Supply to the System
The system is powered as standard with 230 VAC or 115 VAC. To ensure that its op-
eration is maintained even in the event of a mains outage, an external uninterrupt-
ible power supply (UPS) must be used.
4. 4. 1 115/230 V power supply
The system is powered by the supplied power supply unit. The power supply unit is
connected to the mains using a two-pin standard Euro power cable.
The following points are to be observed:
• The mains connector acts as a disconnecting device and must be positioned so
that it is easily accessible.
• Only ever use the supplied power supply unit.
Fig. 26 Powering the system from the mains
-AINS
M
M
0OWERSUPPLYUNIT
SYS
F4
F3
F2
F1
F0
LAN
AUX
PWR
PWR AUDIO