3. 5 System Limits
System limits are defined on the one hand by the existing hardware with its expan-
sion possibilities and on the other by the limits set in the software. The software
limits can be enabled in part by licences.
3. 5. 1 General System Limits
The number of slots, interface cards and system modules per basic system have al-
ready been mentioned in the previous chapters and are not listed separately in this
chapter.
Tab. 14 General system limits
Max. number...
Ascotel®
Intelli-
Gate® 150
Ascotel®
Intelli-
Gate® 300
isyLink
A300 +
A300
AIN with
A300 as
Master
Satellites in an AIN 10
users 20 100 100 100
Terminals per user
1)
16 16 16 16
Simultaneous connections
AD2, a/b, S total (external) 10
2)
30 30+30 cumulated
Internal, total 5
2)
25
2)
30 cumulated
DECT – not DECT (internal / external) 10 20 20
3)
cumulated
DECT – DECT (internal) 5
2)
20 20
3)
cumulated
VoIP – VoIP via SIP access
4)
(external) 8 16 16 32
VoIP – not VoIP (internal / external) 4 18 18+18 cumulated
Voice channels (standard VoIP)
4)
8 18 18+18 cumulated
Voice channels (Voice Mail)
4)
12 12 12+12 cumulated
FoIP channels T.38 1 2 2 cumulated
Trunk groups 20 30 50 90
Trunk groups in route 8 8 8 8
Network interfaces per trunk group 8 8 8 8
Routes 24 24 24 24
B Channel Groups 20 30 50 90
SIP Provider 10 10 10 10
SIP user account 500 500 500 500
Direct Dialling Plans 10 10 10 10
Total DDI numbers 500 500 500 500
Call Distribution Elements 500 500 500 500
User Groups 21 21 21 21
Members per user group with global call distribution 16 16 16 16