Operation Manual / 4 Product description / A130-H.. - A140-H..
Page 79 /
© Copyright 2015 ABB. All rights reserved.
8.4 Removing the gas outlet casing
Marking casing position for assembly
ABB Turbo Systems recommends marking the casing positions prior to
disassembly.
Figure 30: Removing the gas outlet casing
1. Loosen and remove nuts (51009).
2. If present: Loosen the support (61301) from the bracket.
3. Remove the gas outlet casing (61001).
4. Remove the gasket (61002).