Operation Manual / 4 Product description / A130-H.. - A140-H..
Page 11 /
© Copyright 2015 ABB. All rights reserved.
2 Removing and Installing
2.1 Turbocharger weight and transportation
Lifting gear with a sufficient load limit must be used for removing and installing the
turbocharger. The following weight specification applies to the heaviest variant possible.
Depending on the specification, the weight specified on the rating plate may be lower than the
standard value specified here.
A130 190
A135 270
A140 460
Table 2: Turbocharger weights
Figure 5: Suspension of complete turbocharger unit
A Turbocharger with water-cooled bearing casing
B Turbocharger with oil-cooled bearing casing
C Complete turbocharger unit with gas outlet casing