EasyManua.ls Logo

ABB A140-H55 - Page 80

ABB A140-H55
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / 4 Product description / A130-H.. - A140-H..
6
Periodic maintenance work
Page 48 /
115
© Copyright 2015 ABB. All rights reserved.
HZTL4030_EN
Revision C
September 2015
72000 Compressor casing
27000 External water pressure vessel
27005 Sealing plug
01 Water pipe to filter silencer or air suction branch
02 Pressurized air inlet pipe
03 Valve activator
Pressurized air from the compressor casing (72000) of the turbocharger passes through the
pipe (02) to the water pressure vessel (27000). As soon as the valve activator (03) is
activated, water is pressed into the pipe (01) and routed to the filter silencer or air suction
branch.
The water does not act as a solvent. The coating is removed by the mechanical action of the
impacting droplets.

Table of Contents

Related product manuals