EasyManua.ls Logo

ABB A170-M Series - Blanking off the Inlets and Outlets; Engines with Bypass Around the Turbocharger

ABB A170-M Series
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / A170-M.. - A175-M..
10 Taking a turbocharger out of operation / 10.4 Blanking off the inlets
and outlets
© Copyright 2022 ABB. All rights reserved. HZTL4033_EN Rev.K January 2022
Common air receiver
CAUTION
Excessive speeds on undamaged turbochargers
The speed limit n
Bmax
specified on the rating plate of the turbocharger must
not be exceeded. Serious damage to engine or property can be caused by
excessive speeds.
u Observe the speeds of the undamaged turbochargers.
u Reduce the engine load if necessary.
The air line must be blanked off on the engine side because the undamaged turbochargers
build up a receiver pressure.
10.4 Blanking off the inlets and outlets
The chapter is only applicable for engines with several turbochargers and joint air and ex-
haust gas receivers.
u Close the lubricating oil supply to the turbocharger.
u Blank off flange from compressor casing outlet, gas inlet and gas outlet by the installa-
tion of cover plates.
u Observe specifications from enginebuilder.
10.5 Engines with bypass around the turbocharger
The chapter only applies for engines with one turbocharger and for systems on which the
connections for a bypass have been prepared and the necessary pipe connections have been
provided.
u Close the lubricating oil supply to the turbocharger.
u Open the bypass around the turbocharger.
u Observe specifications from enginebuilder.
Page 125 / 146

Table of Contents

Other manuals for ABB A170-M Series

Related product manuals