Maintenance
101
Replacing the additional cabinet fan (frame sizes R7 and R8 only with IP22 and
IP42 when cabling: top entry and bottom exit, bottom entry and top exit or top
entry/exit)
1. Remove the shroud by undoing the fastening screws.
2. Disconnect the fan supply wires (detachable connector).
3. Remove the fan capacitor by undoing the fastening screw of the clamp.
4. Install the new fan and fan capacitor in reverse order to the above.