Parameters 161
35.11 Pros var2 dispf Scaling for process variable 2. This setting also scales the
value for fieldbus.
01 = 1 0
110 = 1 1
2100 = 1 2
3 1000 = 1 3
4 10000 = 1 4
5 100000 = 1 5
35.12 Pros var2 unit Specifies the unit for parameter 04.07 Process var2 (process
variable 2).
0…98 See parameter 35.05 Pros var1 unit.1 = 1
35.13 Pros var2 max Maximum value for process variable 2. See diagram at
parameter 35.09 Signal2 max.
-32768…32768 Maximum value for process variable 2. 1 = 1
35.14 Pros var2 min Minimum value for process variable 2. See diagram at
parameter 35.09 Signal2 max.
-32768…32768 Minimum value for process variable 2. 1 = 1
35.15 Signal3 param Selects a signal to be provided as parameter 04.08 Process
var3.
Speed rpm 01.01 Motor speed rpm (see page 64). 1073742081
Speed % 01.02 Motor speed % (see page 64). 1073742082
Frequency 01.03 Output frequency (see page 64). 1073742083
Current 01.04 Motor current (see page 64). 1073742084
Current % 01.05 Motor current % (see page 64). 1073742085
Torque 01.06 Motor torque (see page 64). 1073742086
Dc-voltage 01.07 Dc-voltage (see page 64). 1073742087
Power inu 01.22 Power inu out (see page 64). 1073742102
Power motor 01.23 Motor power (see page 64
). 1073742103
SpRef unramp 03.03 SpeedRef unramp (see page 71). 1073742595
SpRef ramped 03.05 SpeedRef ramped (see page 71). 1073742597
SpRef used 03.06 SpeedRef used (see page 71). 1073742598
TorqRef used 03.14 Torq ref used (see page 71). 1073742606
Process act 04.03 Process act (see page 72). 1073742851
Proc PID out 04.05 Process PID out (see page 72). 1073742853
Pointer Value pointer setting (see Terms and abbreviations on page
63).
-
No. Name/Value Description FbEq