FB500 ABB_DRIVE_CONTROL_FB
FB500 is used to control the drive (start, stop, reset, emergency stop, speed reference, etc.).
Note: The following description is an example, there are different ways to use the Control function block.
1. In the Program blocks, double-click Main [OB1] and create memory bits for Logic true and Logic
false.
Figure 93 Logic TRUE/FALSE
2. Right-click in the next free network and choose Insert empty box.
Figure 94 Inserting empty box
3. Write FB500 in the block field to create an instance of FB500.
Figure 95 Instance of FB500