APPENDIX G
CoreSense default factory values
The table below contains all the values as they were configured at the factory.
Parameters Description Default value Details
Hydrogen
hydrogen.sensor-offset hydrogen sensor offset correction 0 See “Hydrogen settings”
on page 34.
hydrogen.slope-correction hydrogen slope correction 1.0
hydrogen.roc24h-trigger hydrogen rate of change over 24h trigger
(in ppm/day)
80
hydrogen.level-warning hydrogen level warning (in ppm) 100
hydrogen.level-critical hydrogen level critical (in ppm) 250
hydrogen.roc24h-warning hydrogen rate of change 24h warning 10
hydrogen.roc24h-critical hydrogen rate of change over 24h critical 25
Moisture
moisture.sensor-offset moisture sensor offset correction 0 See “Moisture settings”
on page 35.
moisture.slope-correction moisture slope correction 1
moisture.level-warning moisture level warning (in ppm) 20
moisture.level-critical moisture level critical (in ppm) 30
moisture.roc24h-trigger moisture rate of change over 24h trigger
(in ppm/day)
15
moisture.roc24h-warning moisture rate of change over 24h warning 5
moisture.roc24h-critical moisture rate of change over 24h critical 10
moisture.oil-A moisture oil A 1666.33
moisture.oil-B moisture oil B 7.36
System
system.settings-changes-
allow-on-all-interfaces
Boolean:true See “Communication
settings” on page 37.
system.h2-420-min Integer:0 # Hydrogen 420 value for 4 mA 0
system.h2-420-max Integer:1000 # Hydrogen 420 value for 20 mA 1000
system.h2o-420-min Integer:0 # Moisture 420 value for 4 mA 0
system.h2o-420-max Integer:80 # Moisture 420 value for 20 mA 80
Hardware
hardware.modbus-tcp-port Integer:502 502
hardware.dnp3-tcp-port Integer:20000 20000