20 Installation Guide
For configuration purposes, the sensor can be powered when empty, but the thermal pump must
be turned off (this can be done in the web interface in Settings/administration settings). To prevent
accidents, the CoreSense is delivered with the thermal pump turned off.
When the installation is complete and the sensor is in contact with oil, make sure the thermal pump is
enabled in the web interface.
NOTICE
Operating the heater in air will result in failure of the thermal pump.
Removing the cover
WARNING
Disconnect power from the distribution panel prior to removing the cover.
1 Unscrew the retaining screws from the enclosure cover with the 5 mm Allen key.
2 Remove the enclosure cover.
3 Discard the used o-ring, if necessary.

Table of Contents