236 EtherNet/IP – Communication protocol
Configuration Control attribute (#3) bits
Ethernet link object, class F6h
This object maintains link-specific counters and status information
for the Ethernet communication interface.
Class attributes (Instance #0)
Bit Name Description
0…3 Start-up
configuration
Determines how the device obtains its initial
configuration and start-up.
Value Description
0 The device uses the interface
configuration values previously stored (eg,
in non-volatile memory or via hardware
switches).
1 The device obtains its interface
configuration values via BOOTP.
2 The device obtains its interface
configuration values via DHCP upon start-
up.
3…15 Reserved
4 DNS enable 1 (True) = The device resolves host names by
querying a DNS server.
5…31 Reserved, set to 0.
# Attribute
name
Services Description Data
type
1 Revision Get Revision of the Ethernet Link
Object Class Definition upon
which the implementation is
based
Array of
UINT8

Table of Contents