5 The robot moves to the optimized positions for the wrist axes and
automatically overwrites previous calibration data.
WARNING
Robot moves automatically when pressing Calibrate.
6 Wrist optimization is finished.
7 Redefine / verify TCP for all tools.
Product manual - IRB 1010 303
3HAC081964-001 Revision: B
© Copyright 2022 ABB. All rights reserved.
6 Calibration
6.5 Calibrating with Wrist Optimization method
Continued