Locking liquid: - (Loctite 2400 (or equival-
ent Loctite 243)).
Apply locking liquid to the three screw holes
in the expansion container.
7
Screws: M6x8 (3 pcs).Knock in the VK-cover with a rubber mallet.
Secure with three screws and washers.
xx1500001957
xx1500001956
Remove the plastic plug.8
Apply some grease on the small o-ring and
place it in the recess on the expansion con-
tainer.
9
xx1500001959
Place the expansion container in the base
and place it so the drain holes match.
Tip
Turn and install the container quickly to avoid
oil spill.
10
Secure the expansion container with the at-
tachment screws and washers.
Wipe off any oil residuals before continuing.
11
Tightening torque 6 Nm.