LMT100 AND LMT200 | MAGNETOSTRICTIVE LEVEL TRANSMITTERS | FF OI/LMT100/200/FF-EN REV. A
Menu: Easy Setup (continued)
Menu/Parameter Value Range Description
Easy Setup
Language English, Chinese, Portuguese, German, Spanish, French,
Italian, Russian
Menu language options.
Level Unit (also Volume Unit or
Flow Unit depending on
configurations)
• Unit length
- mm, cm, m, in, ft
• Unit volume
- Liters, cubic meters, cubic inches, cubic feet, cubic
yards, gallons, imperial gallons, bushels, barrels,
liquid barrels
• Unit flow
- Liters/second, liters/minute, liters/hour, gallons/
second, gallons/minute, gallons/hour, gallons/day,
imperial gallons/ second, imperial gallons/minute,
imperial gallons/hour, imperial gallons/day,
barrels/second, barrels/minutes, barrels/hour,
barrels/day, cubic meters/second, cubic meters/
minute, cubic meters/hour, cubic meters/day, cubic
feet/second, cubic feet/ minute, cubic feet/hour,
cubic feet/day
Defines unit of measure for primary variable.
Level LRV (also Volume Level LRV or
Flow LRV depending on
configurations)
Non-linearized

Linearized

Sets lower point which is also the lower range value of the
measuring span.
Level URV (also Volume Level URV
or Flow URV depending on
configurations)
Non-linearized

Linearized

Sets upper point output point which is also the upper
range value for the measuring span.
Interface Level LRV (Only displays
when two floats are attached. May
also display as Volume Interface
LRV, depending on configuration.)
Sets lower range value for liquid interface measuring
span.
Interface Level URV (Only displays
when two floats are attached. May
also display as Volume Interface
URV, depending on configuration.)
Sets upper range value for liquid interface measuring
span.
Level Damping Time  Allows signal smoothing of the signal.
 Raw Level, Distance/Ullage, Level, Interface Select variable to be viewed on display.
Tag alphanumeric 

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB LMT Series and is the answer not in the manual?

ABB LMT Series Specifications

General IconGeneral
BrandABB
ModelLMT Series
CategoryTransmitter
LanguageEnglish

Related product manuals