Menu: Diagnostics (continued)
Menu/Parameter Value Range Description
Diagnostics/History/Elec Temp Min
Elec Temp Minimum Gives minimum recorded temperature of
electronics board
Diagnostics/History/Elec Temp Max
Elec Temp Maximum Gives maximum recorded temperature of
electronics board
Diagnostics/History/Elec Temp Reset
Elec Temp Reset Erases recorded temperature values of
electronics board
Diagnostics/History/Process Temp
Process Temp Gives current temperature of process only
applicable when device equipped with sensor
RTD
Diagnostics/History/Process Temp Min
Process Temp Min Gives minimum recorded temperature of process
Diagnostics/History/Process Temp Max
Process Temp Max Gives maximum recorded temperature of
process
Diagnostics/History/Proc Temp Reset
Proc Temp Reset Resets process temperature
Diagnostics/Group Masking/Maintenance Required
Maintenance Required Enable, Disable Enable or disable diagnostics that fall under this
category
Diagnostics/Group Masking/Check Function
Check Function Enable, Disable Enable or disable diagnostics that fall under this
category
Diagnostics/Group Masking/Off Specification
Off Specification Enable, Disable Enable or disable diagnostics that fall under this
category
Diagnostics/Group Masking/Info None
Info/None Enable, Disable Enable or disable diagnostics that fall under this
category
Diagnostics/Total Run Time
Total Run Time Days Gives total time unit has been operating