13 2TLC172011M0205_B
-DN_Path "6,20 64 24 00 30 3A,D1,1" -DN_Service 16
-Name "plutoAddData_IO14" -UnitType "plutoGateway" -DefValue "0" -OrderNr 36\
-DN_Path "6,20 64 24 00 30 3B,D1,1" -DN_Service 16
-Name "plutoAddData_Node15" -UnitType "plutoGateway" -DefValue "0" -OrderNr 37\
-DN_Path "6,20 64 24 00 30 3C,D1,1" -DN_Service 16
-Name "plutoAddData_IO15" -UnitType "plutoGateway" -DefValue "0" -OrderNr 38\
-DN_Path "6,20 64 24 00 30 3D,D1,1" -DN_Service 16
Normally a gateway connected to ABB robotic system can’t access data areas above this
lines, see size limitations page 4. But it’s still a good behavior to add these lines to
insure that these areas are disabled by setting default value (node 0 and type 0).
-Name "plutoAddData_Node16" -UnitType "plutoGateway" -DefValue "0" -OrderNr 39\
-DN_Path "6,20 64 24 00 30 3E,D1,1" -DN_Service 16
-Name "plutoAddData_IO16" -UnitType "plutoGateway" -DefValue "0" -OrderNr 40\
-DN_Path "6,20 64 24 00 30 3F,D1,1" -DN_Service 16
-Name "plutoAddData_Node17" -UnitType "plutoGateway" -DefValue "0" -OrderNr 41\
-DN_Path "6,20 64 24 00 30 40,D1,1" -DN_Service 16
-Name "plutoAddData_IO17" -UnitType "plutoGateway" -DefValue "0" -OrderNr 42\
-DN_Path "6,20 64 24 00 30 41,D1,1" -DN_Service 16
-Name "plutoAddData_Node18" -UnitType "plutoGateway" -DefValue "0" -OrderNr 43\
-DN_Path "6,20 64 24 00 30 42,D1,1" -DN_Service 16
-Name "plutoAddData_IO18" -UnitType "plutoGateway" -DefValue "0" -OrderNr 44\
-DN_Path "6,20 64 24 00 30 43,D1,1" -DN_Service 16
-Name "plutoAddData_Node19" -UnitType "plutoGateway" -DefValue "0" -OrderNr 45\
-DN_Path "6,20 64 24 00 30 44,D1,1" -DN_Service 16
-Name "plutoAddData_IO19" -UnitType "plutoGateway" -DefValue "0" –OrderNr 46\
-DN_Path "6,20 64 24 00 30 45,D1,1" -DN_Service 16
-Name "plutoAddData_Node20" -UnitType "plutoGateway" -DefValue "0" -OrderNr 47\
-DN_Path "6,20 64 24 00 30 46,D1,1" -DN_Service 16
-Name "plutoAddData_IO20" -UnitType "plutoGateway" -DefValue "0" -OrderNr 48\
-DN_Path "6,20 64 24 00 30 47,D1,1" -DN_Service 16
-Name "plutoAddData_Node21" -UnitType "plutoGateway" -DefValue "0" -OrderNr 49\
-DN_Path "6,20 64 24 00 30 48,D1,1" -DN_Service 16
-Name "plutoAddData_IO21" -UnitType "plutoGateway" -DefValue "0" -OrderNr 50\
-DN_Path "6,20 64 24 00 30 49,D1,1" -DN_Service 16
-Name "plutoAddData_Node22" -UnitType "plutoGateway" -DefValue "0" -OrderNr 51\
-DN_Path "6,20 64 24 00 30 4A,D1,1" -DN_Service 16
-Name "plutoAddData_IO22" -UnitType "plutoGateway" -DefValue "0" -OrderNr 52\
-DN_Path "6,20 64 24 00 30 4B,D1,1" -DN_Service 16
-Name "plutoAddData_Node23" -UnitType "plutoGateway" -DefValue "0" -OrderNr 53\
-DN_Path "6,20 64 24 00 30 4C,D1,1" -DN_Service 16
-Name "plutoAddData_IO23" -UnitType "plutoGateway" -DefValue "0" -OrderNr 54\
-DN_Path "6,20 64 24 00 30 4D,D1,1" -DN_Service 16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB Pluto Series and is the answer not in the manual?

ABB Pluto Series Specifications

General IconGeneral
MountingDIN rail
Current consumptionTypically 100 mA
Communication interfaceEthernet
Protocols supportedModbus TCP, PROFIBUS DP
EnclosureIP20
Supply voltage24 VDC
WeightApprox. 200 g