Function IEC 61850 IEC 60617
ANSI/C37.2 -2008
REF620 REM620 RET620
Three-phase non-directional overcurrent protection, high stage,
instance 4
PHHPTOC4 3I>> (4)
50P-2 (2)
Three-phase non-directional overcurrent protection, high stage,
instance 5
PHHPTOC5 3I>> (5)
50P-1 (3)
Three-phase non-directional overcurrent protection, high stage,
instance 6
PHHPTOC6 3I>> (6)
50P-2 (3)
Three-phase non-directional overcurrent protection, instantaneous
stage, instance 1
PHIPTOC1 3I>>> (1)
50P-3
Three-phase non-directional long time overcurrent protection, lower
stage, instance 1
PHLTPTOC1 3I> (3)
51LT
Three-phase directional overcurrent protection, low stage, instance 1 DPHLPDOC1 3I> -> (1) 67/51P 67/51P(1)
Three-phase directional overcurrent protection, low stage, instance 2 DPHLPDOC2 3I> -> (2) 67/51P(2)
Three-phase directional overcurrent protection, high stage, instance 1 DPHHPDOC1 3I>> -> (1) 67/50P-1
Three-phase directional overcurrent protection, high stage, instance 2 DPHHPDOC2 3I>> -> (2) 67/50P-2
Non-directional earth-fault protection, low stage, instance 1 EFLPTOC1 Io> (1) 51G 51G 51G
Non-directional earth-fault protection, low stage, instance 2 EFLPTOC2 Io> (2) 51N-1 51N (1)
Non-directional earth-fault protection, low stage, instance 3 EFLPTOC3 Io> (3) 51N (2)
Non-directional earth-fault protection, low stage, instance 4 EFLPTOC4 Io> (4) 50SEF 51N (3)
Non-directional earth-fault protection, high stage, instance 1 EFHPTOC1 Io>> (1)
50G-1
50G-1
1)
50G
Non-directional earth-fault protection, high stage, instance 2 EFHPTOC2 Io>> (2)
50G-2
50G-2
2)
Non-directional earth-fault protection, high stage, instance 3 EFHPTOC3 Io>> (3) 50N-1 50N-1 (1)
Non-directional earth-fault protection, high stage, instance 4 EFHPTOC4 Io>> (4) 50N-2 50N-1 (2)
Non-directional earth-fault protection, high stage, instance 5 EFHPTOC5 Io>> (5) 50N-1 (3)
Non-directional earth-fault protection, instantaneous stage, instance 1 EFIPTOC1 Io>>>(1) 50G-3
Non-directional earth-fault protection, instantaneous stage, instance 2 EFIPTOC2 Io>>>(2) 50N-3
Directional earth-fault protection, low stage, instance 1 DEFLPDEF1 Io> -> (1) 67/51N 67/51N 67/51N(1)
Directional earth-fault protection, low stage, instance 2 DEFLPDEF2 Io> -> (2) 67/51N(2)
Directional earth-fault protection, high stage, instance 1 DEFHPDEF1 Io>> -> (1) 67/50N-1
Directional earth-fault protection, high stage, instance 2 DEFHPDEF2 Io>> -> (2) 67/50N-2
Three-phase directional power protection, instance 1 DPSRDIR1 I1-> (1) 32P-1 32P(1)
Three-phase directional power protection, instance 2 DPSRDIR2 I1-> (2) 32P(2)
Ground directional power protection, instance 1 DNZSRDIR1 I2 ->, Io-> (1) 32N-1 32N(1)
Ground directional power protection, instance 2 DNZSRDIR2 I2 ->, Io-> (2) 32N(2)
Phase distance protection, instance 1 PHDSTPDIS1 Z<
21P
21P
3)
Negative-sequence overcurrent protection, instance 1 NSPTOC1 I2> (1) 46-1 46 (1)
Negative-sequence overcurrent protection, instance 2 NSPTOC2 I2> (2) 46-2 46 (2)
Negative-sequence overcurrent protection, instance 3 NSPTOC3 I2> (3) 46 (3)
Phase discontinuity protection PDNSPTOC1 I2/I1> 46PD
Residual overvoltage protection, instance 1 ROVPTOV1 Uo> (1) 59G 59G 59G
Residual overvoltage protection, instance 2 ROVPTOV2 Uo> (2) 59N-1 (1) 59N 59N(1)
Residual overvoltage protection, instance 3 ROVPTOV3 Uo> (3) 59N-1 (2) 59N(2)
Three-phase undervoltage protection, instance 1 PHPTUV1 3U< (1) 27-1 (1)
27-1
1)
27-1 (1)
Three-phase undervoltage protection, instance 2 PHPTUV2 3U< (2) 27-2 (1)
27-2
2)
27-2 (1)
Three-phase undervoltage protection, instance 3 PHPTUV3 3U< (3) 27-1 (2) 27-1 (2)
Three-phase undervoltage protection, instance 4 PHPTUV4 3U< (4) 27-2 (2) 27-2 (2)
Three-phase overvoltage protection, instance 1 PHPTOV1 3U> (1) 59-1 (1)
59-1
1)
59-1 (1)
Three-phase overvoltage protection, instance 2 PHPTOV2 3U> (2) 59-2 (1)
59-2
2)
59-2 (1)
Three-phase overvoltage protection, instance 3 PHPTOV3 3U> (3) 59-1 (2) 59-1 (2)
Table continues on next page
1MAC456939-IB D Section 1
Introduction
620 series ANSI 11
Operation Manual