A070860-ANSI V2 EN
Figure 18: Scroll bar on the right
To scroll the view upwards, press .
To scroll the view downwards, press
.
To jump from the last row to the first row, press again.
Press
to jump from the first row to the last row.
To scroll parameter names and values that do not fit the screen, press . Press
once to return to the beginning.
4.1.9.3 Changing the default view
The default view of the display is Measurements unless set otherwise.
1.
Select Main menu/Configuration/HMI/Default view and press .
2.
Change the default view with or .
3.
Press to confirm the selection.
4.1.10 Viewing single-line diagram
The single-line diagram is created with PCM600. The single-line diagram is active only
when the large screen is used.Upon startup, SLD page 1 is set as the default page.
Select Main menu/Control/SLD to view the single-line diagram or press
to
navigate between main menu, measurement and single-line diagram.