24 - Performance tables
General notes
The performances shown in the following tables are valid with intervention time 100 ms
and temperature and signals within operating limits. If these constraints are not respected,
tolerances can increase.
Ekip Touch sends the TRIP command if the signal read exceeds the threshold for a time
longer than what is set (or resulting from the formula)
With a time-dependent tripping curve the calculation refers to a signal that maintains a
constant value throughout the duration. Any variation of the alarm signal will result in a
different trip time
The supplementary notes are shown after all the tables
Standard
Protections
Protection
[ANSI code]
Trip time t
t
(1)
Trip threshold
tolerance
(3)
Trip time tolerance
L [49]
Curve
t = k/I
2

󰇛


󰇜
Activation for If in the
range:
(1.05-1.2) x I1
± 10 % with If 6 x In
± 20 % with If > 6 In
Curves
60255-
151

󰇧󰇡


󰇢
󰇨
S [50TD / 51]
Curve
t = k
tt = t2
± 7 % with If 6 In
± 10 % with If > 6 In
The better of: ± 10 % or
± 40 ms
Curve
t = k/I
2


± 15 % with If 6 x In
± 20 % with If > 6 In
S2 [50TD]
t
t
= t5
± 7 % with If 6 In
± 10 % with If > 6 In
The better of: ± 10 % or
± 40 ms
I [50]
t
t
30 ms
± 10 %
--
G [50N TD /
51N]
Curve
t = k
t
t
= t4
± 7 %
The better of: ± 10 % o
± 40 ms
(2)
Curve
t = k/I
2

󰇡


󰇢
± 15 %
MCR
t
t
30 ms
± 10 %
--
2I [50]
t
t
30 ms
± 10 %
--
IU [46]
t
t
= t6
± 10 %
The better of: ± 10 % or
± 40 ms with t6 < 5 s;
± 100 ms with t6 5 s
Startup
Protection
Trip time t
t
Trip threshold
tolerance
(3)
Trip time tolerance
S StartUp
t
t
= t2 startup
± 7 % with If 6 In
± 10 % with If > 6 In
The better of: ± 10 % or ± 40 ms
I StartUp
t
t
30 ms
± 10 %
--
G StartUp
t
t
= t4 startup
± 7 %
The better of: ± 10 % or ± 40 ms
S2 StartUp
t
t
= t5 startup
± 7 % with If 6 In
± 10 % with If > 6 In
The better of: ± 10 % or ± 40 ms