116 | XSE RIES G5 | 21060 2 6MN AA
The following is a list of the XSeries
G5
replaceable parts. Part removal method depends on the part
location and connections and enclosure type.
Electronic board
LCD assembly
Lithium battery
12 V battery
Complete XIMV assembly (Transducer)
Serial communication modules (RS-232 and RS-485)
Figure 10-22: Exploded view of an XSeriesG5 enclosure shows an exploded view of the XSeries
G5
flow
computer, which will assist with disassembly and reassembly.
Figure 10-22: Exploded view of an XSeries
G5
enclosure
Table 10-2: Exploded view Legend
Number
Part name
Number
Part Name
Number
Part Name
1
Enclosure
4
Battery tray
7
Lithium battery
2
MMI connector
5
Door latch
8
Electronic board to
transducer cable
3
Door
6
LCD
9
Transducer housing
10.7.1 Replace the 12 Vdc battery
These instructions describe the removal and replacement of the 12 Vdc battery.
NOTICE Loss of data: Do not remove the lithium battery from the electronic board when
removing the 12 Vdc battery. The lithium battery keeps the real-time clock running.