64 | XSE RI ES G5 | 210602 6MNAA
Figure 8-10: Constants tab
Verify or update the following:
For Barometric pressure, type the value, subtracted from the absolute pressure readings
when calibrating in gauge pressure.
IMPORTANT NOTE: Barometric pressure is area-dependent. Use the correct barometric
pressure for the area or the contracted value.
For Orifice diameter, type the diameter in inches.
For Pipe diameter, type the pipe diameter in inches.
For Temperature base (Tb), type the value as defined by the existing contractual
agreement (default is 60 °F).
Click Send.
Continue to the other tabs for additional configuration if needed.
IMPORTANT NOTE: The previous steps are the minimum requirements to get a Totalflow XFC
G5
or XRC
G5
online and measuring gas. There are many more steps depending on the site and
company requirements.
Configure and enable communication interfaces when needed:
Before configuration, wire communication or peripheral equipment to the serial communication
(COMM) terminals. See section 5 Wire COMM ports.
For remote or local network communication, note that enabling Ethernet, Wi-Fi or Bluetooth
will cause additional power consumption.
8.7.1 Configure COM1
The XFC
G5
and XRC
G5
have standard configurations with COM1 configured for remote communications
with a host. COM1 is the name associated with the COMM1 terminal. The port TF-Remote COM1 is
configured to support the Totalflow Remote Protocol by default.
For additional details, click Help from the Communications Setup tab screen.
Configure COM1: