IntroductIon
8
MODEL NUMBER GRID CONNECTION MODEL VARIANT
3W2207
230 / 400 V
50 Hz 32 A
Single charging station with integrated
charging socket according to IEC
62196-2 Type 2 with locking mecha-
nism for separately available charging
cable (Type 2 to Type 2 or Type 2 to
Type 1); integrated, factory deacti-
vated RFID module for access control;
internal
Type A RCCB; internal DC fault
current detection; charging output up
to 22 kW
3W2209
230 / 400 V
50 Hz 32 A
Single charging station with integrated
charging socket according to IEC
62196-2 Type 2 with shutter and lock-
ing mechanism for separately available
charging cable (Type 2 to Type 2 or
Type 2 to Type 1); integrated, factory
deactivated RFID module for access
control; internal Type A RCCB; internal
DC fault current detection; charging
output up to 22 kW
3W2214
230 / 400 V
50 Hz 32 A
T
win charging station with two inte-
grated charging sockets according to
IEC 621
96-2 Type 2 with locking mech-
anism for separately available charging
cable (Type 2 to Type 2 or Type 2 to
Type 1); integrated, factory deacti-
vated RFID module for access control;
internal Type A RCCB; internal DC fault
current detection; internal load man-
agement for charging outputs of up to
2 x 1
1 kW or 1 x 22 kW
3W2217
230 / 400 V
50 Hz 32 A
Twin charging station with two inte-
grated charging sockets according to
IEC 62196-2 Type 2 with shutter and
locking mechanism for separately
available charging cable (Type 2 to
Type 2 or Type 2 to Type 1); integrated,
factory deactivated RFID module for
access control; internal Type A RCCB;
internal DC fault current detection;
internal load management for charging
outputs of up to 2 x 11 kW or 1 x 22
kW