Proceed as follows to test an RCCB:
1. Open the housing cover of the wallbox using the triangular key supplied.
2. Locate the button engraved T or marked Test.
3. Press the button: The corresponding RCCB should now trip and flick the pivot lever
of the RCCB into the 0 position (connection to the power supply is interrupted).
4. Switch the circuit breaker back on by flicking the pivot lever up into the I position.
5. Lock the housing cover of the wallbox using the triangular key.
Danger!
Should one of the RCCBs malfunction during testing, you must not con-
tinue to operate the wallbox under any circumstances! Please contact
your local distributor from whom you have purchased the wallbox.
Taking the wallbox out of and back into operation
If required, you can take your wallbox temporarily or permanently out of operation. To
temporarily deactivate an eMH3 model variant with integrated RCCBs, please proceed
as follows:
1. Open the housing cover of the wallbox using the triangular key supplied.
2. Flick the pivot lever of the internal RCCB(s) into the 0 position (connection to the
power supply is interrupted).
3. Lock the housing cover of the wallbox using the triangular key.
Now the eMH3 cannot be used for charging.
To deactivate your wallbox permanently, also switch off the miniature circuit breaker
(MCB) in your upstream domestic power distribution box (position 0). Now the eMH3
is completely free of electricity and may be demounted if required.
WARNING!
The electrical de-installation of the eMH3 must always be carried out by
a qualified electrical contractor.
ENVIRONMENTAL NOTICE!
Please note that this product may not be disposed of in the household
garbage collection, but must be taken to a collection point for electrical/
electronic waste. Please observe all current national and regional legal
regulations. You can obtain further information from your municipal ad-
ministration, the waste management depot responsible for your area as
well as from your local distributor.