AcerPower Minitower (M11E/IDCATX-2) User's Guide
xxxvi
Table 1-4 System Error Messages (continued)
Message Action
Memory Error at:
MMMM:SSSS:OOO (W:XXXX,
R:YYYY)
where:
M: MB, S: Segment, O: Offset,
X/Y: write/read pattern
Check DIMMs on the system board.
Contact your dealer.
Memory Size Mismatch
CPU Clock Mismatch
Check the memory size and CPU
clock speed installed in the system.
If you are sure that the values are
correct, ignore the message. If the
message reappears, ask for technical
assistance.
Onboard Serial Port 1 Conflict Run Setup (see section 2.1) and
disable the port.
Onboard Serial Port 2 Conflict Run Setup (see section 2.1) and
disable the port.
Onboard Parallel Port Conflict Run Setup (see section 2.1) and
disable the port.
Pointing Device Error Check and connect pointing device.
Pointing Device Interface Error Replace the pointing device or
contact your dealer.
Press F1 key to continue or
Ctrl-Alt-Esc for Setup
Press or
+ + to enter Setup.
Real Time Clock Error Run Setup (see section 2.1) and set
the time and date.
Press Esc to turn off NMI, any
key to reboot
Press to disregard the NMI
error.
Press any other key to reboot.
Real-time Clock Error Run Setup (see section 2.1).