ACTpro 4000 Operating Instructions 1.00
__________________________________________________________________________
the tracking area, however users will not be allowed to re-enter the area until they have been
recorded as exiting, or they may re-enter through a timed anti-passback door after the timed
anti-passback period has expired. If perimeter doors are assigned, then these define the
tracking area, however users may re-enter without restriction. If both are assigned, then the
anti-passback doors and the timed anti-passback doors define the tracking area. The Users
Present output and User Limit A & B outputs operate on the tracking area.
Log in
This function manually enters a user into the area. An event is logged for tracking. This is
typically used when a user has forgotten their card. Manual login is not available if anti-
passback doors are defined – card access MUST be used.
Log out
This function manually removes a user from the area. An event is logged for tracking. This is
typically used when a user has forgotten their card or when they have violated anti-passback
procedures and require entry.
Clear All
This function manually removes all users from the area. An event is logged for tracking. This
is typically used at the end of a day or week to remove any users from the system who have
neglected to use their cards when exiting.
Date/Time
Set Date/Time
The Set Date/Time function allows the operator to adjust the date and time on the controller’s
real-time clock. The built-in clock is normally accurate to within 60 seconds per month and will
occasionally need adjusting to maintain the accuracy of logged events.
The display will prompt the user to enter the correct year (1996-2030), month (1-12), date (1-
31), hour (0-23) and minute (0-59). The seconds will be zeroed. The prompt “Set?” is
displayed on the bottom line of the LCD. The clock will not actually be updated until the key
is pressed, allowing the operator to wait until the time is exactly correct. Any other key will exit
without altering the time.
The day of the week calculation and leap year adjustments are made automatically by
the controller’s internal clock, even if power is not present. ACTWin pro automatically
changes the controller time to match that of the PC.
Time Zones
A time zone is a combination of times and days. Time zones are part of the group
configuration, and provide the times and days when users assigned to a group may have
__________________________________________________________________________________