ACTpro 4000 Operating Instructions 1.00
__________________________________________________________________________
Also any user may be displayed by entering the user number, and then pressing the key
followed by the key.
Pressing the key prompts for a group number to be entered, entering the group number
and pressing the key again assigns the currently displayed user to the group entered.
A range of users may be assigned to the displayed group number, entering the first user
number in the range of users followed by the key, and then entering the last user number
followed the key will assign all the users in the range to the group displayed. This method
can also be used to assign a single user to a group by entering the same user number for the
first and last user in the range.
Assign Options
The Assign Options function allows additional options to be assigned to each of the 60,000
users. The available options are displayed in brackets in the form [23TRA] with non-assigned
options displayed as a dash. Pressing the key allows the options to be altered. When
changing options, the 0 key advances to each option and the key selects or deselects the
displayed option.
Option Description
2 Activate O/P 2
The general-purpose output OP2 is activated for its programmed
duration when this user is granted access.
3 Activate O/P 3
The general-purpose output OP3 is activated for its programmed
duration when this user is granted access.
T Toggle Relay
When the user with toggle capability is granted access, the relay is
toggled so the door will remain permanently open until the next
time the card or token is read. The door must be set for Toggle
Relay operation.
R Extended Relay
Time
If this option is selected the Main Relay will fire for an Extended
time when a user with this option is granted access. The Extended
relay time is set on a door by door basis. See installer menu->door
settings
A Aux Arm/Disarm
Setting this option gives the user the rights to activate/deactivate
an external Alarm. See end of the manual for more details.
Note: The options assigned to an individual user operate in addition to those
assigned to the group.