COM-HPC-ALT User’s Guide PICMG COM-HPC R1.0
Page 18 Copyright © 2023 ADLINK Technology, Inc.
2.10 Mechanical and Environmental
Form Factor and Specification
PICMG COM-HPC Rev 1.0, Server Type, Size D 200 x 160 mm
Operating Temperature
Standard 0°C to 60°C at 12V Storage: -20°C to 80°C
Industrial -20°C to 70°C at 12V Storage: -20°C to 80°C
The module can operate at -40°C to 85°C at 12V if Broacom LAN controller is not populated
Humidity
5-90% RH operating, non-condensing, 5-95% RH storage (and operating with conformal coating)
Shock and Vibration
IEC 60068-2-64 and IEC-60068-2-27
MIL-STD-202F, Method 213B, Table 213-I, Condition A and Method 214A, Table 214-I, Condition D
HALT tested
Thermal Stress, Vibration Stress, Thermal Shock and Combined Test
EMI
EN55032 Class B inside an enclosure