COM-HPC-ALT User’s Guide PICMG COM-HPC R1.0
Page 24 Copyright © 2023 ADLINK Technology, Inc.
GP_SPI_ALERT#
B100
Alert (interrupt) from a Carrier GP_SPI device to the
Module
I 3.3V
PU 10K
4.3.10 Power & System Management
VIN_PWR_OK indicates that all the power to the Module is stable within the specified range and can be used to enable Module internal power supplies.
Name
Pin #
Description
I/O
PU / PD
Comment
PWRBTN#
B02
A falling edge creates a power button event. Power button events
can be used to bring a system out of S5 soft off and other suspend
states, as well as powering the system down.
I 3.3VSB
PU 10K
RSTBTN#
C02
Reset button input. Active low request for Module to reset and
reboot. May be falling edge sensitive. For situations when RSTBTN#
is not able to reestablish control of the system, VIN_PWR_OK or a
power cycle may be used.
I 3.3VSB
PU 90K
PLTRST#
A12
Platform Reset: output from Module to Carrier Board. Active low.
Issued by Module chipset and may result from a low RSTBTN# input,
a low VIN_PWR_OK input, a VCC power input that falls below the
minimum specification, a watchdog timeout, or may be initiated by
the Module software..
O 3.3VSB
VIN_PWR_OK
C06
Power OK from main power supply. A high value indicates that the
power is good. This signal can be used to hold off Module startup to
allow Carrier based FPGAs or other configurable devices time to be
programmed.
I 3.3V
PU 10K
SUS_S3#
B08
Indicates system is in Suspend to RAM state. Active low output. An
inverted copy of SUS_S3# on the Carrier Board should be used to
enable the non-standby power on a typical ATX supply.
Even in single input supply system implementations (AT mode, no
standby input), the SUS_S3# Module output should be used disable
any Carrier voltage regulators when SUS_S3# is low, to prevent bleed
leakage from Carrier circuits into the Module.
O 3.3VSB