MX2820 System Manual
5-56 61186003L1-1D
SETTING T1/E1 THRESHOLDS AND ENABLING ALARMS
Set the thresholds and enable or disable associated alarms from the T1/E1 Statistics screen.
T1/E1 Near-End Daily Thresholds and Alarms
Select NEAR END DAILY THRESHOLDS from the T1/E1 Statistics screen.
Figure 5-28 (see Figure 5-29 for P/N 1186002L3) shows an example of the Near-End Daily
Thresholds menu.
Figure 5-28. T1/E1 Near-End Daily Thresholds
Shelf: 1 Slot: 2A ADTRAN MX2820 System 04/15/04 02:44
Unacknowledged Alarms: TID: HTVLALEXD16
T1/E1 Statistics - Near End Daily Thresholds
Threshold Alarm
1 - CV-L : 387 Disabled
2 - ES-L : 25 Disabled
3 - SES-L : 4 Disabled
4 - LOSS-L : 10 Disabled
5 - AISS-P : 10 Disabled
6 - Restore ALL DS3 and DS1 Threshold Defaults
7 - Enable ALL DS3 and DS1 Threshold Alarms
8 - Disable ALL DS3 and DS1 Threshold Alarms
Selection: '?' - System Help Screen