EasyManua.ls Logo

ADTRAN MX2820 - Provision Vt;Port (T1;E1) Interface; Introduction; Prerequisite Procedures; Vt;Port (T1;E1) Provisioning Data

ADTRAN MX2820
466 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
61186003L1-1D 7-163
DLP-742
Provision VT/Port (T1/E1) Interface
INTRODUCTION
This procedure provides step-by-step instructions to provision the VT/Port (T1/E1) interface
for the STS-1 MUX in the MX2820 system.
PREREQUISITE PROCEDURES
Obtain all necessary local instructions before provisioning the VT/Port (T1/E1) interface. The
parameters need to be set to match the desired application.
VT/PORT (T1/E1) PROVISIONING DATA
Provisioning data includes the following:
•Line State
• Line coding
• Line length
• Loopback detection
• Circuit protection
• T1/E1 Line identification
• Excessive Code Violation (XCV) threshold
• VT Hairpin Loopback
• Cross-Connect Mapping
• VT AIS Transmission
T1/E1 Set Multiple
The Set Multiple parameter (value 29) allows setting the same values for a contiguous group
(or all) of the T1/E1 circuits. To set a value for all T1/E1 circuits, set First to 1 and LAST to
28. Select Apply Settings before leaving the menu. To set a value for only some of the T1/E1
circuits, set First and Last to correspond to the lines desired. Select Apply Settings before
leaving the menu.