80
Troubleshooting Guide
The items included in this section cover the common causes of trouble that an operator might encounter
during the operation of the T-1000-S14. When operating difficulties occur, the best procedure is to
observe what is happening, identify the causes and effect the correction. Make only one adjustment at a
time, checking the results of each adjustment. If an adjustment does not help or escalates the problem(s),
return the settings back to the former position.
CAUTION: These tests and repairs should be performed only by qualified mechanics or electricians
and at their own risk.
Note: When troubleshooting a T-1000-S14 functioning within a system (i.e. with conveyors, scales,
feeders, counters, etc.), always isolate the equipment and operate each machine individually.
Troubleshooting Checklist
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
60 Day Trial Expired screen
appears
60 Day Trial expired
Call APPI Service
Bags not tearing off
1. Continuous Strip is ON
1. Turn Continuous Strip OFF
2. Reverse Distance is too low
2. Increase Reverse Distance
3. Reverse Speed too low
3. Increase Reverse Speed
Low Battery screen appears
It is recommended to replace
battery once every three years.
If the Low Battery Screen displays
on the touch screen, DO NOT turn
off the machine, it will erase the
operating program and any stored
settings. Call APPI Service to
reorder battery and for
replacement instructions.
Touch screen does not display
1. Power off
1. Plug in power cord / turn on
2. Loose connection
2. Tighten connections
3. Fuse blown
3. Replace fuse(s)
4. Contrast out of adjustment
4. Adjust screen contrast
No main power light
1. Blown fuse
1. Replace fuse
2. Bulb out
2. Replace bulb
Pressure bar does not move
when foot switch is operated
1. Disconnected air line/foot
switch
1. Hookup air line
2. Power off
2. Turn on power
Pressure bar moves inward but
does not reach the front plate
(retracts immediately)
1. Anti-jam improperly
adjusted
1. Adjust anti-jam (section 4.12)
2. Misalignment of guide rods
2. Align guide rods (section 4.6)
3. Insufficient air pressure
3. Increase air pressure
4. Loose / broken ground wire
on guide rods
4. Connect / tighten ground wires