5.10.1.3 A Second DHW Storage Tank
(Only After Function Selection)
Offers the possibility to use one of the heating zones for the preparation of a second DHW
storage tank.
EXPERT menu ⇒ Heating circuit I/II ⇒ HC FUNC. “03”
5.10.1.4 Temperature Setting For Second DHW Storage Tank
USER menu ⇒ Heating circuit / II ⇒ T- HW
5.10.1.5 Swimming Pool
Offers the possibility to use one of the heating zone for the heating of a swimming pool.
EXPERT menu ⇒ Heating circuit I/II ⇒ HC FUNC “02”
5.10.1.6 Swimming Pool Temperature Setting
(Only After Function Selection)
USER menu ⇒ Heating circuit I / II ⇒ T- POOL 1 / 2 / 3
5.10.1.7 Screed Dry Program (For Floor Heating Installation)
A program setting for drying the screed.
EXPERT menu ⇒ Installation ⇒ SCREED “01”
5.10.1.8 Temperature Setting For Screed Program
USER menu ⇒ Heating circuit I / II
5.10.1.9 Signal 0 – 10 V
Inlet of 0-10 V signal for slope control through an outer regulator (connect F15).
EXPERT menu ⇒ Solar/MF ⇒ FUNC. F15 “01”
5.10.1.10 Slope And Temperature Setting with 0 – 10 V Signal
See Table 5-7 for values.
EXPERT menu ⇒ Installation ⇒ TENS SLOPE (0 to 11)
EXPERT menu ⇒ Installation ⇒ SLOPE 11 – XX (freely settable)