DCPX - device for low temperatures.
With this accessory correct operation
is possible with outside temperatures
below 20 °C and down to – 10 °C. It
consists of an electronic regulation card
that varies in accordance with the fan
rpms on the basis of the condensation
pressure, read by the high pressure
transducer for the purpose of keeping it
sufficiently high to power the thermostat
valve correctly.
It can only be installed in the factory
for models with heat pumps.
PRD - smart remote panel:
It duplicates the functions of the control
panel on the machine but at a distance.
The maximum installation distance
allowed is 150 m with a six pole
cable (cooling-only version) or seven
pole cable (heat pump versions) plus
shielding, with minimum cross section
of 0.5 sq. mm.
PR1 - simplified remote control panel
It allows basic machine controls to be
performed (turning on and off, changing
function mode, signalling of alarms). The
maximum installation distance allowed is
30 m with a six pole cable (cooling-only
version) or seven pole cable (heat pump
versions) plus shielding, with minimum
cross section of 0.5 sq. mm.
BDX - condensate collection basin:
Condensate collection basin to be
applied to the external unit.
SDP - card for distance adaptation:
Needed to be able install the accessory
PR1 up to 150 m.
KR - Electrical heat exchanger element:
Electric heating element for plate type
exchangers. It prevents the freezing of
the water contained in the evaporator
during winter pauses.
(to be installed in the factory)
RA - Electrical accumulation heating
element :
Electrical accumulation heating element
(in the A versions). It prevents the
freezing of the water contained in the
accumulation during winter pauses.
VT - shock absorbers:
Set of four shock absorbers to fit under
the steel base in the points already
prepared. Their purpose is to dampen the
vibrations produced by the compressor
when it is in operation.
DRE - starting current reduction
device:
It permits the reduction of the starting
current needed by the machine in the
start up phase.
Can only be installed in the factory.
Accessory
PR1 - simplified remote control panel
A
L
A
R
M
PR1 - simplified remote control panel
x100h
SEL
Accessory compatibility table:
DCPX PRD PR1 SDP KR VT DRE (*) BDX RA
ANZ 020
DCPX39

KR2 VT7 BDX5
ANZ 025
DCPX39

KR2 VT7 BDX5
ANZ 030
DCPX39

KR3 VT7 BDX5
ANZ 041
DCPX39

KR3 VT7 BDX5
ANZ 050
DCPX39

KR3 VT7 DRE5 BDX5
ANZ 080
DCPX39

KR3 VT7 DRE5 BDX5
ANZ 090
DCPX39

KR3 VT7 DRE5 BDX6
ANZ 100
DCPX40

KR3 VT8 DRE10
ANZ 150
DCPX40

KR3 VT8 DRE15
ANZ 200
DCPX40

KR3 VT8 DRE15
Versioni ANZ con accumulo
ANZ 020A
DCPX39

VT8 BDX5
ANZ 025A
DCPX39

VT8 BDX5
ANZ 030A
DCPX39

VT8 BDX5
ANZ 041A
DCPX39

VT8 BDX5
ANZ 050A
DCPX39

KR3 VT8 DRE5 (**)
ANZ 080A
DCPX39

KR3 VT8 DRE5 (**)
ANZ 090A
DCPX39

KR3 VT8 DRE5 (**)
ANZ 100A
DCPX40

KR3 VT9 DRE10
ANZ 150A
DCPX40

KR3 VT9 DRE15
ANZ 200A
DCPX40

KR3 VT9 DRE15
(*) = Accessory that can only be installed in the factory
(**) = For models A USE BDX6; for models K or J use BDX7