TECHNICAL MANUAL
Air-cooled heat pumps with high-efficiency scroll
compressor
ISO 9001 - Cert. n° 0128/4
IANZTV. 0709 - 6755120_03
R
R
407C
407C
anz
ENGLISH
MANUAL TÉCNICO
Bombas de calor condensadas por aire con compresor
scroll de alta eficacia
Español
Question and Answer IconNeed help?

Do you have a question about the AERMEC ANZ 020 and is the answer not in the manual?

Summary

Declaration of Conformity

Compliance with Standards

Details the compliance with European directives and harmonized standards for refrigerating systems and materials.

General Standards and Warranty

Manual and Installation Guidelines

Instructions for manual upkeep, careful installation, and adherence to safety and local regulations.

Warranty Conditions and Exclusions

Covers warranty voiding due to tampering, improper use, non-authorised repairs, and other exclusions.

Unit Description and Selection

ANZ Series Overview

Air-cooled heat pumps for medium/small users, featuring high-efficiency scroll compressors and quiet operation.

Available Versions and Options

Explains model sizing and configuration options to meet specific plant requirements.

Product Configurator

Model Naming and Configuration Options

Details the model naming convention and configuration choices for power supply, materials, and specific features like heat pumps.

Component Descriptions

Chiller Circuit and Hydraulic Components

Describes compressors, heat exchangers, filters, expansion tanks, and accumulation tanks.

Electrical Systems and Control

Explains electrical panel, electronic card, electronic regulation, and control unit functions.

Frame and Fan Unit

Describes the unit's covering furniture and the balanced fan unit with safety protections.

Safety and Checking Components

Pressure and Temperature Safety Switches

Details high/low pressure switches, high-temperature thermostat, and differential pressure/flow switches for safety.

Microprocessor Functions and Display

Lists microprocessor functions like temperature adjustment, compressor control, alarm management, and parameter display.

Available Accessories

Remote Control and Low Temperature Accessories

Covers PRD/PR1 remote panels, DCPX low-temperature device, and SDP distance adaptation card.

Heating and Ancillary Accessories

Details KR/RA heating elements, VT shock absorbers, DRE current reduction, and BDX condensate basin.

Accessory Compatibility Overview

A table summarizing accessory compatibility across different ANZ models.

Technical Cooling Data (No Accumulation)

Cooling Performance and Energy Indices

Tables for cooling capacity, input power, water flow, and EER across various models.

Electrical, Compressor, and Evaporator Specs

Data on power supply, FLA, LRA, compressor/fan types, and evaporator details.

Dimensions and Sound Data

Tables detailing physical dimensions, weight, and sound pressure levels for the units.

Technical Heating Data (No Accumulation)

Heating Performance and Energy Indices

Tables for heating capacity, input power, water flow, and COP across various models.

Electrical, Compressor, and Evaporator Specs

Data on power supply, FLA, LRA, compressor/fan types, and evaporator details.

Dimensions and Sound Data

Tables detailing physical dimensions, weight, and sound pressure levels for the units.

Technical Cooling Data (With Accumulation)

Cooling Performance and Hydraulic Capacities

Tables for cooling capacity, input power, water flow, expansion tank, and accumulation tank capacities.

Electrical, Compressor, and Evaporator Specs

Data on power supply, FLA, LRA, compressor/fan types, and evaporator details for units with accumulation.

Dimensions and Sound Data

Tables detailing physical dimensions, weight, and sound pressure levels for units with accumulation.

Technical Heating Data (With Accumulation)

Heating Performance and Hydraulic Capacities

Tables for heating capacity, input power, water flow, expansion tank, and accumulation tank capacities.

Electrical, Compressor, and Evaporator Specs

Data on power supply, FLA, LRA, compressor/fan types, and evaporator details for units with accumulation.

Dimensions and Sound Data

Tables detailing physical dimensions, weight, and sound pressure levels for units with accumulation.

Operating Limits and Selection

Cooling and Heating Limit Diagrams

Diagrams illustrating operational limits based on air and water temperatures for cooling and heating.

Correction Coefficients for Glycol and Dirtying

Explains diagrams for correction coefficients related to glycol water usage and exchanger dirtying.

Installation and Wind Protection Notes

Advises on installation in non-salty environments and the need for wind breaks in windy positions.

Cooling Capacity and Input Power Adjustments

Correction Diagram for Cooling Performance

Diagram for obtaining cooling capacity and input power correction coefficients based on water and external air temperatures.

Applying Cooling Correction Coefficients

Guidance on using the diagram to adjust cooling capacity and input power for H versions.

Heating Capacity and Input Power Adjustments

Correction Diagram for Heating Performance

Diagram for obtaining heating capacity and input power correction coefficients based on outside air temperature.

Applying Heating Correction Coefficients

Guidance on using the diagram to adjust heating capacity and input power for H versions.

Pressure Drop Data

Evaporator and Water Filter Pressure Drops

Charts showing pressure drops for evaporators and water filters based on water flow rate.

Pressure Drop Correction Factors

Table providing correction factors for evaporator pressure drops based on average water temperature.

Storage Tank and Glycol Solutions

Storage Tank Installation and Content

Notes on storage tank installation, plug replacement, and maximum water content for plant compatibility.

Glycol Solution Correction Factors Table

Table of correction factors for glycol solutions at various concentrations and operating temperatures.

Expansion Tank Calibration

Expansion Tank Pressure and Calibration

Details expansion tank pressure charge, maximum value, and calibration formula based on height difference.

Plant Static Pressure Graph

Graph showing available static pressure for the plant in relation to water flow rate for different ANZ models.

Ethylene Glycol Solution Effects

Glycol Correction Factor Diagram and Key

Diagram and key explaining correction factors for cooling capacity, input power, and pressure drops based on glycol percentage.

Applying Glycol Correction Factors

Guidance on applying correction factors for water flow rate and pressure drops when using glycol.

Reading Glycol Correction Curves

Glycol Percentage Determination

Instructions on using diagrams to find glycol percentage and correction coefficients based on air or water temperatures.

Temperature Linkage Note

Clarification that outside air and processed water temperatures are not directly linked on the graph.

Correction Factors and Calibration

Delta T and Fouling Correction Factors

Tables for correction factors based on temperature differences (Δt) and fouling factors for performance adjustments.

Sound Data and Control Calibration

Details acoustic power, sound pressure, and calibration settings for control parameters and protection devices.

Electric Absorption and Heater Options

Supplementary Heater Power and Versions

Information on supplementary heater power, K/J versions, and installation locations.

Boiler Kit Accessory Compatibility

Table detailing compatibility of various boiler kits (BW4KW, BW5KW) for ANZ K/J models.

System Connection Diagrams

Illustrates system configurations for AK/AJ versions, showing key components and connections.

Advanced Control Unit (RE037 A)

Control Unit Functionality and Formula

Manages three-way valve for radiant panels, with temperature calculation formula and probe usage.

Control Unit Description and Settings

Details unit components, indicators, factory settings, and adjustment trimmers for optimal operation.

Heat Compensation Logic

Self-Compensation and Parameter Definitions

Explains self-compensation of water set based on outside temp and defines key parameters (rL, r3, rF, rE).

Compensation Logic Diagrams

Diagrams illustrating heat compensation logic for radiating panels and fan coils based on temperatures.

Size Data (ANZ 0207-0307)

ANZ 0207;0257 H and HA;HK;HJ Dimensions

Technical drawings showing dimensions and connections for ANZ 0207/0257H and HA/HK/HJ models.

ANZ 0307 H and HA;HK;HJ Dimensions

Technical drawings showing dimensions and connections for ANZ 0307H and HA/HK/HJ models.

Size Data (ANZ 0417-0807)

ANZ 0417 H and HA;HK;HJ Dimensions

Technical drawings showing dimensions and connections for ANZ 0417H and HA/HK/HJ models.

ANZ 0507 H;080 H and 050 HA;080 HA Dimensions

Technical drawings showing dimensions and connections for ANZ 0507H/080H and 050HA/080HA models.

Size Data (ANZ 0907-2007)

ANZ 0907 H and HA Dimensions

Technical drawings showing dimensions and connections for ANZ 0907H and HA models.

ANZ 1007 H;1507 H;2007 H and HA Dimensions

Technical drawings showing dimensions and connections for ANZ 1007/1507/2007H and HA models.

Size Data (ANZ 0507-0807 With Accumulation)

ANZ 050 HAK;050 HAJ Dimensions

Technical drawings for ANZ 050HAK/050HAJ models with accumulation and electric heater.

ANZ 080 HAK;080 HAJ Dimensions

Technical drawings for ANZ 080HAK/080HAJ models with accumulation and electric heater.

Size Data (ANZ 0907-1007 With Accumulation)

ANZ 0907 HAK;0907 HAJ Dimensions

Technical drawings for ANZ 0907HAK/0907HAJ models with accumulation and electric heater.

ANZ 1007 HAK;1007 HAJ Dimensions

Technical drawings for ANZ 1007HAK/1007HAJ models with accumulation and electric heater.

Size Data (ANZ 1507-2007 With Accumulation)

ANZ 150 HAK;150 HAJ Dimensions

Technical drawings for ANZ 150HAK/150HAJ models with accumulation and electric heater.

ANZ 200 HAK;200 HAJ Dimensions

Technical drawings for ANZ 200HAK/200HAJ models with accumulation and electric heater.

Summary

Declaration of Conformity

Compliance with Standards

Details the compliance with European directives and harmonized standards for refrigerating systems and materials.

General Standards and Warranty

Manual and Installation Guidelines

Instructions for manual upkeep, careful installation, and adherence to safety and local regulations.

Warranty Conditions and Exclusions

Covers warranty voiding due to tampering, improper use, non-authorised repairs, and other exclusions.

Unit Description and Selection

ANZ Series Overview

Air-cooled heat pumps for medium/small users, featuring high-efficiency scroll compressors and quiet operation.

Available Versions and Options

Explains model sizing and configuration options to meet specific plant requirements.

Product Configurator

Model Naming and Configuration Options

Details the model naming convention and configuration choices for power supply, materials, and specific features like heat pumps.

Component Descriptions

Chiller Circuit and Hydraulic Components

Describes compressors, heat exchangers, filters, expansion tanks, and accumulation tanks.

Electrical Systems and Control

Explains electrical panel, electronic card, electronic regulation, and control unit functions.

Frame and Fan Unit

Describes the unit's covering furniture and the balanced fan unit with safety protections.

Safety and Checking Components

Pressure and Temperature Safety Switches

Details high/low pressure switches, high-temperature thermostat, and differential pressure/flow switches for safety.

Microprocessor Functions and Display

Lists microprocessor functions like temperature adjustment, compressor control, alarm management, and parameter display.

Available Accessories

Remote Control and Low Temperature Accessories

Covers PRD/PR1 remote panels, DCPX low-temperature device, and SDP distance adaptation card.

Heating and Ancillary Accessories

Details KR/RA heating elements, VT shock absorbers, DRE current reduction, and BDX condensate basin.

Accessory Compatibility Overview

A table summarizing accessory compatibility across different ANZ models.

Technical Cooling Data (No Accumulation)

Cooling Performance and Energy Indices

Tables for cooling capacity, input power, water flow, and EER across various models.

Electrical, Compressor, and Evaporator Specs

Data on power supply, FLA, LRA, compressor/fan types, and evaporator details.

Dimensions and Sound Data

Tables detailing physical dimensions, weight, and sound pressure levels for the units.

Technical Heating Data (No Accumulation)

Heating Performance and Energy Indices

Tables for heating capacity, input power, water flow, and COP across various models.

Electrical, Compressor, and Evaporator Specs

Data on power supply, FLA, LRA, compressor/fan types, and evaporator details.

Dimensions and Sound Data

Tables detailing physical dimensions, weight, and sound pressure levels for the units.

Technical Cooling Data (With Accumulation)

Cooling Performance and Hydraulic Capacities

Tables for cooling capacity, input power, water flow, expansion tank, and accumulation tank capacities.

Electrical, Compressor, and Evaporator Specs

Data on power supply, FLA, LRA, compressor/fan types, and evaporator details for units with accumulation.

Dimensions and Sound Data

Tables detailing physical dimensions, weight, and sound pressure levels for units with accumulation.

Technical Heating Data (With Accumulation)

Heating Performance and Hydraulic Capacities

Tables for heating capacity, input power, water flow, expansion tank, and accumulation tank capacities.

Electrical, Compressor, and Evaporator Specs

Data on power supply, FLA, LRA, compressor/fan types, and evaporator details for units with accumulation.

Dimensions and Sound Data

Tables detailing physical dimensions, weight, and sound pressure levels for units with accumulation.

Operating Limits and Selection

Cooling and Heating Limit Diagrams

Diagrams illustrating operational limits based on air and water temperatures for cooling and heating.

Correction Coefficients for Glycol and Dirtying

Explains diagrams for correction coefficients related to glycol water usage and exchanger dirtying.

Installation and Wind Protection Notes

Advises on installation in non-salty environments and the need for wind breaks in windy positions.

Cooling Capacity and Input Power Adjustments

Correction Diagram for Cooling Performance

Diagram for obtaining cooling capacity and input power correction coefficients based on water and external air temperatures.

Applying Cooling Correction Coefficients

Guidance on using the diagram to adjust cooling capacity and input power for H versions.

Heating Capacity and Input Power Adjustments

Correction Diagram for Heating Performance

Diagram for obtaining heating capacity and input power correction coefficients based on outside air temperature.

Applying Heating Correction Coefficients

Guidance on using the diagram to adjust heating capacity and input power for H versions.

Pressure Drop Data

Evaporator and Water Filter Pressure Drops

Charts showing pressure drops for evaporators and water filters based on water flow rate.

Pressure Drop Correction Factors

Table providing correction factors for evaporator pressure drops based on average water temperature.

Storage Tank and Glycol Solutions

Storage Tank Installation and Content

Notes on storage tank installation, plug replacement, and maximum water content for plant compatibility.

Glycol Solution Correction Factors Table

Table of correction factors for glycol solutions at various concentrations and operating temperatures.

Expansion Tank Calibration

Expansion Tank Pressure and Calibration

Details expansion tank pressure charge, maximum value, and calibration formula based on height difference.

Plant Static Pressure Graph

Graph showing available static pressure for the plant in relation to water flow rate for different ANZ models.

Ethylene Glycol Solution Effects

Glycol Correction Factor Diagram and Key

Diagram and key explaining correction factors for cooling capacity, input power, and pressure drops based on glycol percentage.

Applying Glycol Correction Factors

Guidance on applying correction factors for water flow rate and pressure drops when using glycol.

Reading Glycol Correction Curves

Glycol Percentage Determination

Instructions on using diagrams to find glycol percentage and correction coefficients based on air or water temperatures.

Temperature Linkage Note

Clarification that outside air and processed water temperatures are not directly linked on the graph.

Correction Factors and Calibration

Delta T and Fouling Correction Factors

Tables for correction factors based on temperature differences (Δt) and fouling factors for performance adjustments.

Sound Data and Control Calibration

Details acoustic power, sound pressure, and calibration settings for control parameters and protection devices.

Electric Absorption and Heater Options

Supplementary Heater Power and Versions

Information on supplementary heater power, K/J versions, and installation locations.

Boiler Kit Accessory Compatibility

Table detailing compatibility of various boiler kits (BW4KW, BW5KW) for ANZ K/J models.

System Connection Diagrams

Illustrates system configurations for AK/AJ versions, showing key components and connections.

Advanced Control Unit (RE037 A)

Control Unit Functionality and Formula

Manages three-way valve for radiant panels, with temperature calculation formula and probe usage.

Control Unit Description and Settings

Details unit components, indicators, factory settings, and adjustment trimmers for optimal operation.

Heat Compensation Logic

Self-Compensation and Parameter Definitions

Explains self-compensation of water set based on outside temp and defines key parameters (rL, r3, rF, rE).

Compensation Logic Diagrams

Diagrams illustrating heat compensation logic for radiating panels and fan coils based on temperatures.

Size Data (ANZ 0207-0307)

ANZ 0207;0257 H and HA;HK;HJ Dimensions

Technical drawings showing dimensions and connections for ANZ 0207/0257H and HA/HK/HJ models.

ANZ 0307 H and HA;HK;HJ Dimensions

Technical drawings showing dimensions and connections for ANZ 0307H and HA/HK/HJ models.

Size Data (ANZ 0417-0807)

ANZ 0417 H and HA;HK;HJ Dimensions

Technical drawings showing dimensions and connections for ANZ 0417H and HA/HK/HJ models.

ANZ 0507 H;080 H and 050 HA;080 HA Dimensions

Technical drawings showing dimensions and connections for ANZ 0507H/080H and 050HA/080HA models.

Size Data (ANZ 0907-2007)

ANZ 0907 H and HA Dimensions

Technical drawings showing dimensions and connections for ANZ 0907H and HA models.

ANZ 1007 H;1507 H;2007 H and HA Dimensions

Technical drawings showing dimensions and connections for ANZ 1007/1507/2007H and HA models.

Size Data (ANZ 0507-0807 With Accumulation)

ANZ 050 HAK;050 HAJ Dimensions

Technical drawings for ANZ 050HAK/050HAJ models with accumulation and electric heater.

ANZ 080 HAK;080 HAJ Dimensions

Technical drawings for ANZ 080HAK/080HAJ models with accumulation and electric heater.

Size Data (ANZ 0907-1007 With Accumulation)

ANZ 0907 HAK;0907 HAJ Dimensions

Technical drawings for ANZ 0907HAK/0907HAJ models with accumulation and electric heater.

ANZ 1007 HAK;1007 HAJ Dimensions

Technical drawings for ANZ 1007HAK/1007HAJ models with accumulation and electric heater.

Size Data (ANZ 1507-2007 With Accumulation)

ANZ 150 HAK;150 HAJ Dimensions

Technical drawings for ANZ 150HAK/150HAJ models with accumulation and electric heater.

ANZ 200 HAK;200 HAJ Dimensions

Technical drawings for ANZ 200HAK/200HAJ models with accumulation and electric heater.

AERMEC ANZ 020 Specifications

General IconGeneral
BrandAERMEC
ModelANZ 020
CategoryHeat Pump
LanguageEnglish