3 For the interface card location you will be using, using a Torx T10
screwdriver, remove the screw securing the slot cover; then, remove the
slot cover.
4 Insert the interface card into the appropriate slot:
a Ensure that the tab on the board’s rear panel is aligned with the slot
in the deck.
b Press the board securely into the socket on the motherboard.
c Replace the screw.
5 Replace the cover.
CAUTION
When reinstalling the handle assembly, ensure that the screws are torqued to 2.372
Newton meters (21 inch pounds) so that they do not work themselves loose.