-221 Settings conflict; frequency has been adjusted
The requested output (or carrier) frequency is not valid. The output
frequency is automatically adjusted if you select a function whose
maximum frequency is less than that of the currently active function.
For example, if you output a 1 MHz sine wave and then change the
function to triangle wave, the function generator will adjust the output
to 100 kHz (the upper limit for triangle waves).
-221 Settings conflict; fsk frequency has been adjusted
The requested
FSKhop” frequency is not valid. The FSK frequency is
automatically adjusted if you select a function whose maximum
frequency is less than that of the currently active function. For example,
if you set the
FSK frequency to 1 MHz in the sine function and then
change the function to triangle wave, the function generator will adjust
the frequency to 100 kHz (the upper limit for triangle waves).
-221 Settings conflict; offset has been adjusted
The requested offset voltage is not valid with the present output
amplitude. The offset is automatically adjusted to the maximum value
allowed with the present output amplitude. The output amplitude
(in Vpp) and the dc offset voltage must obey the following restrictions.
(Vmax is either 10 volts for a high impedance termination or 5 volts
for a 50 ohm termination.)
-221 Settings conflict; start frequency has been adjusted
The requested start frequency is not valid. The start frequency is
automatically adjusted if you select a function whose maximum
frequency is less than that of the currently active function. For example,
if you set the start frequency to 200 kHz in the sine wave function and
then change the function to triangle wave, the function generator will
adjust the output to 100 kHz (the upper limit for triangle waves).
Ô
V
offset
Ô
+
V
pp
2
Vmax and
Ô
V
offset
Ô
2 x V
pp
5
Chapter 5 Error Messages
Execution Errors
233

Table of Contents

Other manuals for Agilent Technologies 33120A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 33120A and is the answer not in the manual?

Agilent Technologies 33120A Specifications

General IconGeneral
BrandAgilent Technologies
Model33120A
CategoryInverter
LanguageEnglish

Related product manuals