Startup and configuration
4. Log in to the Web server of the station to
be configured
1. Apply power to the station.
• Power is supplied by a PoE compatible switch.
• The status indicator flashes (orange) when the station is starting.
• The status indicator will light up blue once the station has started.
2. Start the PC and open the one of the before mentioned web browsers.
3. Enter the address below in the address bar of the browser to access the configuration Web server.
IPv4 example - https://IP address of this device/webset.cgi?login
• Enter the IP address of the station to be configured.
• IPv6 example - https://[IP address of this device]/webset.cgi?login
• The default IP address is 192.168.1.160, and the subnet mask is 255.255.255.0.
4. A certificate error screen is displayed. Click [Go on to the webpage].
Note
• If a station cannot be accessed, press and hold the reset button until the status indicator flashes orange. The IP Address,
Subnet Mask, Administrator ID, Administrator Password, User ID, and User Password will return to default. Access the device
within one minute of resetting.
Important
• To prevent the certificate error, perform the procedures described in “CSR (→page 83)” and “SSL Certificate (→page 85)”.