EasyManua.ls Logo

Alcatel-Lucent 7210 - 7210 SAS-M Overview; Table 18: Alarm Interface Port Pinouts

Alcatel-Lucent 7210
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7210 SAS-M Overview
7210 SAS-M Installation Guide Page 21
RTN refers to the negative side of the floating external power supply. This power supply must not
be connected to chassis ground and should be 18-50 volts DC at 100 ma. Please refer to Appendix ,
“Appendix C: Alarm Pin Assignments,” on page 83 for further information.
8 ALARM_IN1_EXT_+ External alarm input 1 (external relay dry contact closure
to pin 15).
9 CRIT_ALARM_NC Normally closed during Critical alarm state.
10 MJR_ALARM_CNTR Common contact for Major alarm relay.
11 MJR_ALARM_NO Normally open during Major alarm state.
12 ALARM_IN4_EXT_RTN External alarm input 4 (external relay dry contact closure
from pin 5).
13 ALARM_IN3_EXT_RTN External alarm input 3 (external relay dry contact closure
from pin 6).
14 ALARM_IN2_EXT_RTN External alarm input 2 (external relay dry contact closure
from pin 7).
15 ALARM_IN1_EXT_RTN External alarm input 1 (external relay dry contact closure
from pin 8).
Table 4: Alarm Interface Port Pinouts
Pin Name Function

Table of Contents