Management Port Pin Assignments
Page 80 7210 SAS-M Installation Guide
Management Port Pin Assignments
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 
connections and 100-ohm Category 3, 4, or 5 cable for 10 Mbps connections or 100-
ohm Category 5 cable for 100 Mbps connections. Make sure that the length of any 
twisted-pair connection does not exceed 100 meters (328 feet). 
The RJ-45 ports on the switch base unit support automatic MDI/MDI-X operation, so 
you can use straight-through cables for all network connections to PCs or servers, or to 
other switches or hubs. In straight-through cable, pins 1, 2, 3, and 6, at one end of the 
cable, are connected straight through to pins 1, 2, 3, and 6 at the other end of the cable. 
When using any RJ-45 port on these switches, you can use either straight-through or 
crossover cable. 
Table 16:  10/100BASE-TX MDI and MDI-X Port Pinouts
Pin   MDI Signal Name   MDI-X Signal Name 
1   Transmit Data plus (TD+)   Receive Data plus (RD+) 
2   Transmit Data minus (TD-)   Receive Data minus (RD-) 
3   Receive Data plus (RD+)   Transmit Data plus (TD+) 
6   Receive Data minus (RD-)   Transmit Data minus (TD-) 
4, 5, 7, 8   Not used   Not used 
NOTE:
•  The “+” and “-” signs represent the polarity of the wires that make up each wire pair. 
•  Auto-negotiation must be enabled for automatic MDI/MDI-X pinout configuration.