Alarm Port Pin Assignments
Page 86 7210 SAS-M Installation Guide
Figure 17: Alarm Input Connection Diagram
RTN refers to the negative side of the floating external power supply. This power
supply must not be connected to chassis ground and should be 18-50 volts DC at 100
ma.
Major and Critical alarm dry relay contact outputs are provided on pins 3,10,11 and
1,2,9. These reflect the major and critical alarms output by the box and can be
manually cleared by pressing the ACO button.
The 4 alarm inputs are customer configurable to monitor alarms provided by
additional equipment. These inputs require a separate DC power supply between 18-