Configuration Commands
Page 288 7750 SR OS Interface Configuration Guide
The port’s OTU must be enabled to set or change the FEC mode.
The port must be shut down before changing the FEC mode.
The sf-sd-method must be changed to BIP8 before setting the FEC mode to disabled.
The no form of the command disables FEC encoder and decoder.
Default no fec
Parameters enhanced — Enables the FEC encoder and decoder with a proprietary enhanced FEC algorithm.
g709 — Enables the FEC encoder and decoder with the standard G.709 FEC algorithm.
otu2-lan-data-rate
Syntax otu2-lan-data-rate {11.049 | 11.0957}
Context config>port>otu
Description This command specifies the data rate to use when configured for an OTU encapsulated 10GE-LAN
signal. The port must be shut down before changing the 10GE LAN OTU2 data rate.
Default 11.049
Parameters 11.049 Configures the port to transmit and receive an 11.049 Gb/s synchronous OTU
encapsulated 10GE-LAN signal ( No fixed stuffing bytes in the OTU2 frame).
11.0957 — Configures the port to transmit and receive an 11.0957 Gb/s synchronous OTU
encapsulated 10GE-LAN signal (with fixed stuffing bytes in the OTU2 frame).
sf-sd-method
Syntax sf-sd-method {bip8 | fec}
Context config>port>otu>sf-sd-method
Description This command specifies the method used to determine the signal fail and signal degrade alarms.
When select the bip8 method is selected, the SM-BIP8 errors are used. When the FEC method is
selected, the FEC corrected bits are used.
The following rules must be followed:
The port’s OTU must be enabled to set or change the sf-sd-method.
The FEC mode must be enhanced or g709 before setting the sf-sd-method to fec.
The SF threshold must be 5 or higher before setting the sf-sd-method to bip8.
Default fec
Parameters bip8 The SM-BIP8 errors are used to declare the presence of the Signal Fail and Signal Degrade
condition.