Interface Configuration
7750 SR OS Interface Configuration Guide Page 289
fec  — The FEC corrected bit errors are used to declare the presence of the Signal Fail and Signal 
Degrade condition.
sf-threshold
Syntax sf-threshold threshold
Context config>port>otu>sf-threshold
Description This command specifies the error rate at which to declare the signal fail condition for the the signal 
fail (SF) threshold. The value represents an error rate of 10E-<value>.
The SF threshold must:
• Be less than the SD threshold.
• Be 5 or higher before setting the sf-sd-method to bip8.
Default 4
Parameters threshold — Specifies the signal fail (SF) threshold.
Values 3 —7
sd-threshold
Syntax sd-threshold threshold
Context config>port>otu>sd-threshold
Description This command specifies the error rate at which to declare the signal fail condition for the signal 
degrade (SD). The value represents an error rate of 10E-value.
The SD threshold must::
• Be greater than the SF threshold.
• Be 5 or higher before setting the sf-sd-method to bip8.
Default 7
Parameters threshold — Specifies the exponent of the error rate,  thus an error rate from 10E-3 to 10E-7.
Values 5 — 9 
sm-tti
Syntax sm-tti
Context config>port>otu
Description This command enables the context to configure section monitoring trail trace identifier parameters.