Table 3-29 Alarm/Status Connector J305 Mating Cable Wiring and Pinout
ALM/STATUS/CONTROL PIN PR
WIRE
COLOR
REMARKS
A XMT ALM OUT 01 1 WHT/BLU ALARM OUTPUT FROM RELAY INTFC
B XMT ALM OUT 26 BLU/WHT ALARM OUTPUT FROM RELAY INTFC
A RCV ALM OUT 02 2 WHT/ORN ALARM OUTPUT FROM RELAY INTFC
B RCV ALM OUT 27 ORN/WHT ALARM OUTPUT FROM RELAY INTFC
CONTROLLER FAIL ALM
OUT
03 3 WHT/GRN ALARM OUTPUT FROM RELAY INTFC
SWITCH I/O OUT 28 GRN/WHT CONTROL OUTPUT FROM RELAY INTFC
SWITCH XMTR OUT 04 4 WHT/BRN CONTROL OUTPUT FROM RELAY INTFC
SWITCH RCVR OUT 29 BRN/WHT CONTROL OUTPUT FROM RELAY INTFC
A XMT IN SVCE OUT 05 5 WHT/SLT STATUS OUTPUT FROM RELAY INTFC
B XMT IN SVCE OUT 30 SLT/WHT STATUS OUTPUT FROM RELAY INTFC
A RCV IN SVCE OUT 06 6 RED/BLU STATUS OUTPUT FROM RELAY INTFC
B XMT IN SVCE OUT 31 BLU/RED STATUS OUTPUT FROM RELAY INTFC
A I/O IN SVCE OUT 07 7 RED/ORN STATUS OUTPUT FROM RELAY INTFC
B I/O IN SVCE OUT 32 ORN/RED STATUS OUTPUT FROM RELAY INTFC
PWR SUPPLY ALM OUT 08 8 RED/GRN ALARM OUTPUT FROM RELAY INTFC
NOT USED/OPEN
DOOR FAULT
33 GRN/RED ALARM OUTPUT ON COMM PAK ONLY
STATION ALM 9 IN 09 9 RED/BRN RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 1 IN 34 BRN/RED RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 10 IN 10 10 RED/SLT RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 2 IN 35 SLT/RED RELAYINPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 11 IN 11 11 BLK/BLU RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 3 IN 36 BLU/BLK RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 12 IN 12 12 BLK/ORN RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 4 IN 37 ORN/BLK RELAY INPUT FROM CUSTOMER
EQUIPMENT