3.11 DS3 REPEATER (J401 ON ONE SHELF TO J401 ON SECOND SHELF)
The DS3 repeater cable carries clocks, data, and overhead for two direc-
tions. It does not carry DS3 or wayside DS1 traffic. DS3 and wayside DS1
cables must be run separately. If the 401 cable is not used, the embedded
data in the overhead must be cabled individually. In this case, individual
cables must be run for MCS-11, audio, RS-232, and ELMC.
Recommended connectorized cable assembly – PN 695-7836-001/005 (25 pair shielded
cable with 50 pin Amp connectors) (SCSI). See Figure 3 - 10 for shelf connector location and
pinout. Refer to CD for mating cable wiring and color code.
Use repeater cables for cabling repeater shelf 1 to repeater shelf 2 (east-
bound/westbound data/clock).
Table 3 - 7 Wayside DS1 Mating Cable – DS3 LBO
J201 (INPUTS) 202 (OUTPUTS)
FUNCTION END 1 WIRE COLOR WIRE COLOR END 2 FUNCTION
LINE 1 TIP IN 01 BLACK BLACK 01 LINE 1 TIP OUT
LINE 1 RING IN 06 RED RED 06 LINE 1 RING OUT
LINE 2 TIP IN 02 BLACK BLACK 02 LINE 2 TIP OUT
LINE 2 RING IN 07 WHITE WHITE 07 LINE 2 RING OUT
LINE 3 TIP IN 04 BLACK BLACK 04 LINE 3 TIP OUT
LINE 3 RING IN 08 GREEN GREEN 08 LINE 3 RING OUT
NOT USED 05 BLACK BLACK 05 NOT USED
NOT USED 09 BLUE BLUE 09 NOT USED
GND 03 BLACK GND 03 NOT USED
NOT USED 10 YELLOW YELLOW 10 NOT USED